LC-120 series

LC-120 series

Laser sensors short form Laser sensors short form (2,24MB)
Manuals, software, other downloads Manuals, software, other downloads
Print this page Print this page
LC-120 series
The LC-120 series is suitable for high precision detection. Choose between versions with background suppression or polarised retroreflective types. This laser class 2 sensor with background suppression allows objects to be detected regardless of colour. The LC-120 features a very small laser spot and short response time with excellent repeatability, making it ideal to detect very small objects or slight movements.

Characteristics:

  • Trigonometric sensors with 150mm and 350mm rated sensing distance
  • Excellent price-performance ratio
  • Retroreflective types with polarising filter (20m)
  • Diffuse reflective type with background suppression available
  • Rotary connector available

Accessories:

  • Cable
  • Reflectors
  • Mounting brackets

NPN output LC-120-PL2000-A-P-J LC-120-BL0015-A-P-J LC-120-BL0035-A-P-J
PNP output LC-120-PL2000-A-P-PN-J LC-120-BL0015-A-P-PN-J LC-120-BL0035-A-P-PN-J
[A] = Axial, [P] = Plastic, [PN] = PNP, [J] = M12 Connector
Sensor type Reflective with polarising filter Diffuse with BGS
Rated sensing distance 20m 150mm 350mm
Sensing range 0.3 to 20m 30 to 150mm 50 to 350mm
Spot diameter (approx.) Ø 0.5mm at 0,5m 0.2mm at 60mm 0.4mm at 150mm
Standard sensing object Metal, black Paper, white
Ø 6mm 100x100mm
Detection capability Opaque, semitransparent Opaque, transparent
Hysteresis -- < 1%
Response time 200#s 140#s 200#s
Transistor output Max. 100mA
Emitting element Red laser diode, 645 to 665nm (laser class 2)
Current consumption without load max. 30mA
Housing Enclosure: ABS
Lens: PMMA
Protection IP67
Dimensions (HxWxD) Cable type: approx. 50x50x18mm
Connector type: approx. 50x66x18mm
Connection Cable 2m or M12 Connector
Operating voltage 10 to 30VDC
Ambient temperature Operation: -10 to +50°C, Storage: -25 to +70°C
Weight (approx.) 40g
LC-120 typical applications
Foil detection
Foil detection
Pharmaceutical industry, e.g. blister package detection
Pharmaceutical industry, e.g. blister package detection




 
Callback

More information

 
Back
Print this page
 
 
 
Privacy statement

© 2005-2012 Panasonic Electric Works Europe AG
ID: MTMzNzE5OTU4OA
Imprint

Terms & conditions
Site map